Directionally
Drilled
Spray Ball
Assemblies
Have complete confidence in your CIP
process with directionally drilled sprays
Directionally Drilled Spray Ball Assemblies
As Clean-In-Place (CIP) system experts for pharmaceutical industries, Sani-Matic has extensive experience designing spray solutions with proper flows, pressures and exact spray patterns to ensure validatable cleaning for your process vessels.
Sani-Matic’s directionally drilled spray ball assemblies meet the latest ASME BPE standards including designs for complete spray coverage, full drainability, proper finish, borescope-inspected orbital welds, and alignment pins for exact, repeatable installation.
Designing for Your Process with Custom-Engineered Solutions
Sani-Matic creates 3-D models of your process vessels to engineer static spray devices with exact drill patterns for full spray coverage of all ports and surfaces to meet validation requirements.
ASME BPE design and testing standards for spray devices such as flow rate recommendations and riboflavin testing procedures are followed and Sani-Matic designers work to understand and identify all potential component process contact surfaces to ensure surface finish specifications are accurate.
Resources
View brochures, manuals, technical datasheets, or watch videos for this product.
Articles
Read articles written by industry leaders to share their expertise and recommendations.
Product Resources
Literature
Videos
Product Details
Standard Features
○ 316Lss
○ Process contact finish: 15 μin Ra
○ Non-process contact finish: 32 μin Ra
○ Alignment positioning pin
○ Orbital Welds
○ CNC drilled spray holes
○ Passivation and Electropolish (optional)
Exact drill patterns ensure full spray coverage
Directionally Drilled Spray Ball Assembly
Documentation (CDP-Premium Package)
Other Packages Available
○ Material Test Reports (MTRs)
○ 3-A Certificate
○ Sani-Matic Certificate of Conformance (CoC)
○ Certified “As-Built” Drawings
○ Heat Map
○ Weld Map
○ Weld Log
○ Surface Finish Certification
○ Electropolish Certification
○ Passivation Certification